Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.

References

1.
Holden
,
J. P.
,
Orsini
,
J. A.
,
Siegel
,
K. L.
,
Kepple
,
T. M.
,
Gerber
,
L. H.
, and
Stanhope
,
S. J.
, 1997, “
Surface Movement Errors in Shank Kinematics and Knee Kinetics During Gait
,”
Gait and Posture
,
5
(
2
), pp.
217
227
.
2.
Andriacchi
,
T. P.
, and
Alexander
,
E. J.
, 2000, “
Studies of Human Locomotion: Past, Present and Future
,”
J. Biomech.
,
33
(
10
), pp.
1217
1224
.
3.
Leardini
,
A.
,
Chiari
,
L.
,
Della Croce
,
U.
, and
Cappozzo
,
A.
, 2005, “
Human Movement Analysis Using Stereophotogrammetry. Part 3. Soft Tissue Artifact Assessment and Compensation
,”
Gait and Posture
,
21
(
2
), pp.
212
225
.
4.
Alexander
,
E. J.
, and
Andriacchi
,
T. P.
, 2001, “
Correcting for Deformation in Skin-Based Marker Systems
,”
J. Biomech.
,
34
(
3
), pp.
355
361
.
5.
Andriacchi
,
T. P.
,
Alexander
,
E. J.
,
Toney
,
M. K.
,
Dyrby
,
C.
, and
Sum
,
J.
, 1998, “
A Point Cluster Method for in Vivo Motion Analysis: Applied to a Study of Knee Kinematics
,”
J. Biomech. Eng.
,
120
(
6
), pp.
743
749
.
6.
Cereatti
,
A.
,
Della Croce
,
U.
, and
Cappozzo
,
A.
, 2006, “
Reconstruction of Skeletal Movement Using Skin Markers: Comparative Assessment of Bone Pose Estimators
,”
J. NeuroEng. Rehabil.
,
3
(
7
), published online.
7.
Delp
,
S. L.
,
Anderson
,
F. C.
,
Arnold
,
A. S.
,
Loan
,
P.
,
Habib
,
A.
,
John
,
C. T.
,
Guendelman
,
E.
, and
Thelen
,
D. G.
, 2007, “
Opensim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
,”
IEEE Trans. Biomed. Eng.
,
54
(
11
), pp.
1940
1950
.
8.
Camomilla
,
V.
,
Cereatti
,
A.
,
Vannozzi
,
G.
, and
Cappozzo
,
A.
, 2006, “
An Optimized Protocol for Hip Joint Centre Determination Using the Functional Method
,”
J. Biomech.
,
39
(
6
), pp.
1096
1106
.
9.
Delp
,
S. L.
,
Loan
,
J. P.
,
Hoy
,
M. G.
,
Zajac
,
F. E.
,
Topp
,
E. L.
, and
Rosen
,
J. M.
, 1990, “
An Interactive Graphics-Based Model of the Lower Extremity to Study Orthopaedic Surgical Procedures
,”
IEEE Trans. Biomed. Eng.
,
37
(
8
), pp.
757
767
.
10.
Benoit
,
D. L.
,
Ramsey
,
D. K.
,
Lamontagne
,
M.
,
Xu
,
L.
,
Wretenberg
,
P.
, and
Renstrom
,
P.
, 2007, “
in Vivo Knee Kinematics During Gait Reveals New Rotation Profiles and Smaller Translations
,”
Clin. Orthop. Relat. Res.
,
454
, pp.
81
88
.
11.
Lafortune
,
M. A.
,
Cavanagh
,
P. R.
,
Sommer
,
H. J.
, III
, and
Kalenak
,
A.
, 1992, “
Three-Dimensional Kinematics of the Human Knee During Walking
,”
J. Biomech.
,
25
(
4
), pp.
347
357
.
12.
Cappozzo
,
A.
,
Catani
,
F.
,
Leardini
,
A.
,
Benedetti
,
M. G.
, and
Croce
,
U. D.
, 1996, “
Position and Orientation in Space of Bones During Movement: Experimental Artefacts
,”
Clin. Biomech. (Bristol, Avon)
,
11
(
2
), pp.
90
100
.
13.
Bey
,
M. J.
,
Kline
,
S. K.
,
Tashman
,
S.
, and
Zauel
,
R.
, 2008, “
Accuracy of Biplane X-Ray Imaging Combined with Model-Based Tracking for Measuring in-Vivo Patellofemoral Joint Motion
,”
J. Orthop. Surg. Res.
,
3
(
38
), published online.
14.
Jonsson
,
H.
, and
Karrholm
,
J.
, 1994, “
Three-Dimensional Knee Joint Movements during a Step-Up: Evaluation after Anterior Cruciate Ligament Rupture
,”
J. Orthop. Res.
,
12
(
6
), pp.
769
779
.
15.
Tashman
,
S.
, and
Anderst
,
W.
, 2003, “
In-Vivo Measurement of Dynamic Joint Motion Using High Speed Biplane Radiography and Ct: Application to Canine Acl Deficiency
,”
J. Biomech. Eng.
,
125
(
2
), pp.
238
245
.
16.
Defrate
,
L. E.
,
Papannagari
,
R.
,
Gill
,
T. J.
,
Moses
,
J. M.
,
Pathare
,
N. P.
, and
Li
,
G.
, 2006, “
The 6 Degrees of Freedom Kinematics of the Knee after Anterior Cruciate Ligament Deficiency: An in vivo Imaging Analysis
,”
Am. J. Sports Med.
,
34
(
8
), pp.
1240
1246
.
17.
Komistek
,
R. D.
,
Dennis
,
D. A.
, and
Mahfouz
,
M.
, 2003, “
in Vivo Fluoroscopic Analysis of the Normal Human Knee
,”
Clin. Orthop. Relat. Res.
,
410
, pp.
69
81
.
18.
Stiehl
,
J. B.
,
Komistek
,
R. D.
,
Dennis
,
D. A.
,
Paxson
,
R. D.
, and
Hoff
,
W. A.
, 1995, “
Fluoroscopic Analysis of Kinematics after Posterior-Cruciate-Retaining Knee Arthroplasty
,”
J. Bone Joint Surg. Br.
,
77
(
6
), pp.
884
889
.
19.
Torry
,
M. R.
,
Shelburne
,
K. B.
,
Peterson
,
D. S.
,
Giphart
,
J. E.
,
Krong
,
J. P.
,
Myers
,
C.
,
Steadman
,
J. R.
, and
Woo
,
S. L.
, “
Knee Kinematic Profiles During Drop Landings: A Biplane Fluoroscopy Study
,”
Med. Sci. Sports Exercise.
,
43
(
3
), pp.
533
541
.
20.
Winter
,
D. A.
, 1984, “
Kinematic and Kinetic Patterns in Human Gait: Variability and Compensating Effects
,”
Hum. Mov.Sci.
,
3
(
1–2
), pp.
51
76
.
21.
Andriacchi
,
T. P.
,
Briant
,
P. L.
,
Bevill
,
S. L.
, and
Koo
,
S.
, 2006, “
Rotational Changes at the Knee after Acl Injury Cause Cartilage Thinning
,”
Clin. Orthop. Relat. Res.
,
442
, pp.
39
44
.
22.
Gok
,
H.
,
Ergin
,
S.
, and
Yavuzer
,
G.
, 2002, “
Kinetic and Kinematic Characteristics of Gait in Patients with Medial Knee Arthrosis
,”
Acta Orthop. Scand.
,
73
(
6
), pp.
647
652
.
23.
Arnold
,
A. S.
,
Blemker
,
S. S.
, and
Delp
,
S. L.
, 2001, “
Evaluation of a Deformable Musculoskeletal Model for Estimating Muscle-Tendon Lengths During Crouch Gait
,”
Ann. Biomed. Eng.
,
29
(
3
), pp.
263
274
.
You do not currently have access to this content.