Active vibration control requires a velocity signal which is fed back to the force actuator to produce the damping force to the structure. Usually a gap sensor is used to detect the displacement and a differentiator is needed to produce the velocity signal. Moreover, it is very difficult to install the sensor at the same position of the actuator. Setting the gap sensor close to the magnetic actuator may cause an undesirable interaction between them. Sometimes there is no space for installing the sensor. This paper introduces a method of using a moving-coil-type actuator as a two-port sensing and driving device. Four types of velocity identification algorithms are tested and their capability of reducing structural vibrations is compared.

1.
Balas, G. J., and Doyle, J. C., 1990, “Collocated Versus Non-collocated Multivariable Control for Flexible Structure,” Proc. of American Control Conference, TP12, pp. 1923.
2.
Kalman
R. E.
, and
Bucy
R. S.
,
1961
, “
New Results in Linear Filtering and Prediction Problems
,”
ASME Journal of Basic Engineering, Ser. D.
, Vol.
38
, No.
1
, pp.
95
108
.
3.
Lindner
D. K.
,
Celano
T. P.
, and
Ide
E. N.
,
1991
, “
Vibration Suspension Using a Proofmass Actuator Operating in Stroke/Force Saturation
,”
ASME JOURNAL OF VIBRATION AND ACOUSTICS
, Vol.
113
, October, pp.
423
433
.
4.
Luenberger, D. G., 1966, “An Introduction to Observers,” IEEE Trans. AC-16, pp. 596–602.
5.
Mizuno, T., Bleuler, H., Gahler, C., and Visher, D., 1992, “Towards Practical Applications of Self-Sensing Magnetic Bearings,” Proc. of the 3rd Int. Symp. on Magnetic Bearings, Alexandria, VA, July 29-31.
6.
Okada
Y.
, and
Nakada
T.
,
1976
, “
Analysis and Experiments on an Electro-Hydraulic Torsional Servo Vibration Damper
,”
Bull, of the JSME
, Vol.
19
, No.
131
, May, pp.
477
484
.
7.
Okada, Y., 1978, “Analysis and Application of the Electro-Magnetic Servo Damper,” Proc. of the 19th Int. Machine Tool Design and Research Conf., Manchester, Sept. 13–15, pp. 481–486.
8.
Okada, Y., Matsuda, K., and Nagai, B., 1992, “Sensorless Magnetic Levitation Control by Measuring the PWM Carrier Frequency Component,” Proc. of the 3rd Int. Symp. on Magnetic Bearings, Alexandria, VA, July 29–31.
9.
Visher, D., and Bleuler, H., 1990, “A New Approach to Sensorless and Voltage Controlled AMB’s Based on Network Approach,” Proc. of 2nd Int. Symp. on Magnetic Bearings, July 12–14, Tokyo, pp. 301.
10.
Zimmerman
D. C.
,
Horner
G. C.
, and
Inman
D. J.
,
1988
, “
Microprocessor Controlled Force Actuator
,”
Journal of Guidance and Control
, Vol.
11
, No.
3
, pp.
230
236
.
This content is only available via PDF.